Df fuse catalog pdf. The rated breaking class l fuses.


The first fuses were simple, open-wire devices, followed in the Schneider Electric USA. 4 Operator voltage of the blown fuse indicator: 110V…690V. gI-gG and aM fuse-links are for industrial applications. pdf - Free download as PDF File (. The rated breaking capacity is 120 kA. Adds a 10 A max ATM fuse circuit by inserting into an existing ATM fuse block with 5 inch #16 leadwire and crimp connector - fuses not included BP/HHA-RP Adds a 10 A max ATC fuse circuit by inserting into an existing ATC fuse block with 5 inch #16 leadwire and crimp connector - fuses not included Fuses sold separately. com 2 Low oltage supplemental fuses Fuse holder and block selection guide Catalog pages for the blocks and holders are denoted parenthetically "()" next to their catalog symbol. ×11/2" length). Rated breaking capacity. Fax: (918) 663-8615. fuse links dfelectric. Current rating. The rated breaking class l fuses. · IP20 Security accessory in terminal zones. These high breaking capacity fuse-links are intended for protection of power lines and equipment, against overloads and short-circuits with rated voltages up to 500V AC (+10%). Table 5. They are only to be used when the associated circuit has been de-energized. 86 mb: 1_Fuse-Links. They are available in four sizes (DI, DII, DIII and DIV) with ratings from 2A to 100A and rated voltage of 500V AC. 2 Nº 65 Wire connectors dfelectric. NOTE : • Insulated gripping lugs can not be used. This catalog provides features and ordering information for Eaton's Cooper Power series dual element Bay-O-Net fuse link used in Bay-O-Net fuse assemblies which protect distribution apparatus from damaging currents and distribution systems from failed app aratus. Without a fuse it would be 67. Solar Products Catalog Circuit protection products for photovoltaic applications PDF Download: English High-Speed fuse catalog Littelfuse high-speed (semiconductor) fuses protect critical power electronics from overcurrents that may cause damage to your equipment. pdf Related products. Remote control unit 6. UltraSafe holders qualify as “Finger- R-Rated fuses are back-up fuses that provide short-circuit protection for motor circuits. txt) or read online for free. Designed and based on substantial experience of elec trical safety, the switch fuse eliminates the risk of electrical accidents: - The fuse covers cannot be opened while the switch fuse is in the ON-position and can be sealed in the closed position. Type of Fuse. com Accessories for type D Fuse links Table 4. 1) B B C A Recommended CLE and HLE Jan 1, 2016 · Brochure for a advanced function miniature circuit breakers. wide range of physical sizes and ampere ratings for 250, 400, 500, and 690 volts AC. All about switches Making and breaking current Isolating Fuse combination units Function Switch Disconnector Fuse-switch single break Fuse-disconnector single break Switch-fuse single break Disconnector-fuse single break a a Switch-fuse double break Disconnector-fuse double break Switch-fuse double DF Electric 420002 10A Cylindrical Fuse 10×38(Pack 10) Cylindrical fuse-links gG class for use as general protection against overloads and short circuits, intended as protection of cables, power lines, and equipment. Download PDF. Manufactured with ceramic body with high withstand to internal pressure and thermal shock, that allows a high breaking Open the catalog to page 4. 25ID JTD 1-1⁄ of the downstream equipment. 10×85 gS Cylindrical fuse link 1000V AC/DC; gPV Catalogues high voltage fuses. The fuse helps protect three-phase motors for single-phase operation. 10×85 gS Cylindrical fuse link 1000V AC/DC; gPV Cylindrical fuse links. Standards:DIN43620 Part 1 Ordering Code:Rating/Type/Body Size/Category e. 10×38 gPV Cylindrical fuse links Sep 21, 2020 · Fuses catalogue 2020. 064 (2. All Rights Reserved. This represents the value of the current that the fuse can carry continuously with out deterioration under specified conditions. Do not perform connection work with live wires. Sheet 2 Rated Voltage 250V Breaking Capacity(AC) 35A or 10 In whichever is greater Rated Current (In) Overload Min Max All 2. CURRENTLIMITING 200,000 AMPS RMS SYMMETRICAL CSAClass 1422-02 Line Load Configuration Conductors Max fuse class and Amp* Catalog number Openings per pole Line Load JTRK1 RK5 Amps Wire range Wire range AWG or AWG or LPJ JJS LPS-RK FRS-R SCCR - Pole Line Load kcmil kcmil JJN LPN-RK FRN-R PDB204-1 PDB204-3 175A 2/0 - 8 AWG Cu 2/0 - 8 AWG Cu 2/0 - 8 2/0 - 8 200 200 200 60 200kA Catalogue (. fuse or link P = Poles Sold in lots of Catalog numbers Weight A kg (oz) 30 Class CC 1 P 12 DFCC1V 0. 100NH2G-690 5-2-00 SB99216 Rev. 012"H) up to the 5 AG (13/32" diameter. It will be automatically reset after the blown fuse has been replaced and the green LED turns on again. 240 Volt Fuse Series Ratings 63 - 68 480V Series Ratings 69 - 92 480 Volt Fuse Series Ratings 93 - 95 600V Series Rating 96 - 98. Voltage ratings may be colour coded to reduce the risk of incorrect installation. Compatible fuse holders (ordered separately , only for use with bladed version) † SD1-D † SD2-D † SD3-D Catalogue number Energy integrals I2t (A2S) Watts loss Bladed with lugs Blade with bolt holes no lugs Fuse body size Current rating (Amps) Pre-arcing Total at 800 V a. Rated Thermal Current. 25KV, 15. Fusing + pre-breaking + fuse link detection · Only detection of fuse link operation · Also as accessory mounted on standard fuse holders FIG. Digital Update: 2022/23 Catalogue Download PDF. 46. HRC Fuse-link range is available in 14x51 Cylindrical, DIN and BS type. 5 A – 315 A. For wires of section ≤10 mm2. 46 • UL® Listed, Guide JEEG, File E240398. Proper Coordination Between Overload Relay and Branch Circuit Fuses Improves Motor Starter Protection Mar 15, 2016 · LFJ60 series fuse holder LFPSJ series (8⁄ 10 – 60 A) fuse holder Ordering Information AMPERE CATALOG NUMBER PRODUCT MARKING PACK QUANTITY ORDERING NUMBER UPC AGENCY APPROVALS UL CSA 0. Fusesaver™ 3. SEMICONDUCTOR FUSE LINKS RAPIDPLUS® range comprise three sizes with dimensions 10x38, 14x51 and 22x58, with rated Open the catalog to page 4 Full Fuse Catalog — SOC Corporation is a global manufacturer of fuses and a leader in fuse technology, covering a wide range of fields including EV, home electronics, medical equipment, and automotive electronics. 37-18 Northern Blvd, Long Island City, NY 11101. 10×38 BAC Open fuse base; 14×51 BAC Open fuse base; 22×58 BAC Open fuse base; Clip contact for Ø10 fuse links; HORUS® PHOTOVOLTAIC. 3 22,000 70 125 100 QPH,BQH,BLH 70 POWR-SPEED® Fuse Llttelfuse* Expertise Applied | Answers Delivered PSR SERIES HIGH-SPEED SQUARE BODY FUSES Semiconductor Fuses • Flush End • 40 A - 2000 A Specifications Voltage Range Amperage Range Interrupting Range Time Constant Microswitch Mounting Material Approvals Description Littelfuse PSR Series High-Speed Square Body Fuses are specially designed for protection of power Fuse base 1-Pole, NH4 2100605 NH2 and NH3 NH4a and NH4 2021308. 3 Medium-voltage Fuses - product catalog. 01. High voltage fuses, US-standard (HHA): Download. 2 kAp i. ; At I = 32 kA , 315 A fuse limits the cut-off current to 26rms kAp. 7 times the fuse Sensata High Voltage Fuses Catalog 2020 HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS ' ' SEMICONDUCTOR FUSE LINKS USE OF SEMICONDUCTOR FUSE LINKS (RAPIDPLUS) IN PMC, PMF & PMX MODULAR FUSE HOLDERS AND The modular fuse holders for cylindrical fuses have a rated power acceptance according to the maximum power dissipations allowed for the general use fuse links (gG) and back up fuse links All 38 kV fuse links must only be used in series with a 38 kV rated ELSP current-limiting backup fuse or equivalent. pdf), Text File (. es. . 75 In 10ms 500ms >100mA 50ms 2s 100mA 4. pdf: 2016-09-19: Norberg~IES 4237 South 74th East Avenue Tulsa, Oklahoma 74145. Our Bussmann series products refl ect a longstanding tradition of leading fusible circuit protection and electrical safety solutions that protect equipment and enable reliable, effi cient power distribution. rating number rating number rating number rating number 100 a4bq100 500 a4bq500 1000 a4bq1000 2000 a4bq2000 150 a4bq150 600 a4bq600 1200 a4bq1200 2500 a4bq2500 200 a4bq200 601 a4bq601 1350 a4bq1350 2501 a4bq2501 The switch fuse ensures safe operation, protecting both people and equipment. Rated Conditional S/C current (rms) with fuses @ 690V AC kA 80 80 80 Rated Conditional S/C current (rms) with fuses @ 500V AC kA 100 100 100 Degree of Protection with Fuse & Terminal cover (from front - panel door open) IP20 IP20 IP20 Auxiliary Switch: General Data for 3KL8 Switch Disconnector Fuse 3KL8 1/2 3KL8 3/4 REF 420000 / 420001 / 420002 / 420004 / 420006 / 420008 / 420010 / 420012 / 420016 / 420020 / 420025 / 420032 / 420102 / 420104 / 420106 / 420108 / 420110 / 420112 DIN Type (Knife Edge) fuses Fusing current time curves of Bolted type fuses upto 800A e. Vietnam(Vietnamese) Nhãn hiệu của chúng tôi PMC Compact fuse holders. Application FP-2 13/32" to 13/16" diameter fuses FP-3 1" to 1-3/4" diameter. 00 In 3ms 100ms >100mA 10ms 300ms All 10. fuses and fuse blocks to meet your overcurrent protection needs. Cylindrical Fuse links. 27. amp-trap 2000 ® a4bq. Catalogue number Fuse link size To fit fuse base type Current (Amps) Pack qty CD27 10×38 PMC Compact fuse holders; PMX CC fuse holders; BAC Open fuse bases. fuses greater than 100 amps must melt in 600 seconds at an RMS current within the range of 220% to 264% of the fuse’s nameplate current rating. c. They are applied with medium voltage motor starters which provide the overload protection for the circuit. © 2024 SOC Corporation. Full range of rated current, voltage available as well as compatible fuse holders. DF223C - Fuse carrier, TeSys DF, 3P, 125A, 690VAC, fuse size 22x58mm. after the use of the fuse, the short-circuit force is reduced to 15% of the value that is possible without the effect of the fuse. Ferraz Shawmut gF, gI-gG and aM fuse-links cover a . 000V DC. 5KV, 25. 1) B B C A Recommended fuseclips and dfelectric. · All the versions with label FuPact GSB Switch-Disconnectors Fuses range from 32 to 1250A catalog . Phone: (918) 665-6888 (800) 739-9145. Eaton's Bussmann British standard fuses can be used in multiple applications; industrial, utility, street lighting and domestic. Process Calibration Tools Catalog. < Previous. Scribd is the world's largest social reading and publishing site. Short Data Description BS fuse holders DF101 - Fuse carrier, TeSys DF, 1P, 32A, 690VAC, fuse size 10x38mm. 355 2. /V a. The document presents a number of available and most effective protective devices for various applications along with selection guidelines and detailed technical data. pdf . Battery terminal fuses BTF-1P, BTF-2P, BTF-3P, BTF-5P 11 Multi slow-blow fuses MUSB 11 High-amp stud-mount fuses/blocks AMG/HMEG, AMI/HMID 12 Fuse holders and taps ATR fuse holder HH2 13 ATM-LP fuse holders HHV 13 ATM fuse holders HHL, HHM, HHU, ATM-FHID 13 ATC fuse holders HHC, HHD, HHF, HHG, HHR, HHS, ATC-FHID 13 MAXI fuse holders HHX, MAX Enjoy the best free PDF reader with Adobe. Next > Was this helpful? Yes No High Speed Fuses and Fusegear Catalog - MERSEN Product Selection Guide - Circuit Protection, Fuses, Power DF ELECTRIC 485101 | Fuse holder; cylindrical fuses; 10. · Accessory available to lock the fuse holder by a padlock. 56 / 65 Accessories Article Description 800 Fuse base 1-Pole, NH4 2100601 Standard (NH000-NH3) W/ leather sleeve (NH000-NH3) 2200105 Article Number Page 2112002 Grip handle, insertion / removal tool 601 602 604 Page Fuse base 1-Pole, NH3 2100501 Fuse base 1-Pole, NH4a a5 e1 a1 PHOTOVOLTAIC FUSE HOLDERS PMX 5x20 FUSE HOLDERS FOR PHOTOVOLTAIC APPLICATIONS 1000V The first feature that PV Modular fuse holders offers, is the 1000V DC rated voltages. 186 (6. The fuse limits the Cylindrical fuse links for photovoltaic applications gPV 10x38 cylindrical fuse links from DF Electric have been developed to offer a compact, safety and economic protection of photovoltaic modules (string protection) with voltages up to 1. com 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2. For mounting on DIN/EN rail. Federal NH fuses are manufactured of steatite material and capable of breaking short circuit currents up to 120 kArms. 30 Feb 20, 2024 · DF ELECTRIC 420002 Cylindrical Fuse 10×38. Conductor 2. Applications The fuses are ideally suited for protection of lighting and heating circuits and can be used in industrial as well as in building application. com Bussmann Series Electrical Catalog - Free ebook download as PDF File (. Its enhanced fuse construction Fuse holders with microswitch 5A - 250V 2. 5 kV, Rated currents: 0. sc 100NHG000B - Eaton Bussmann series low voltage NH Fuse, Live gripping lug, 500V, 100A, 120 kAIC, Combination fuse status indicator, Blade end connection, Class C gL/gG, square-body with knife blade contact, Metal plated copper contact plat-100NHG000B 5 Tightening screws too tight may damage the terminals. Skip To Main Content. 1 0E–225E . 2 (H) RW12(PD1)-12F Series Outline Drawing Drop-Out Fuse Series RW12(PD1)-12 RW12(PD1)-12F HRW12(HPD1)-12 addition to the protection offered by fuses. These high breaking capacity fuse-links are intenKnife 500V 690V ded for short circuit protection in motors, transformer and other load with high inrush currents, with rated voltages up to 500V AC (+10%) and 690V AC (+5%). Fuse carrier TeSys DF, 3P 50A, fuse size 14x51 mm, blown fuse indicator May 30, 2022: DF143VC: 149Kb / 3P: Fuse carrier TeSys DF, 3P 50A, fuse size 14x51 mm, blown fuse indicator DF142: 127Kb / 3P: Fuse carrier TeSys DF, 2P 50A, fuse size 14x51 mm DF141: 117Kb / 3P: Fuse carrier TeSys DF, 1P 50A, fuse size 14x51 mm May 30, 2022: DF142: 139Kb Voltage rating. 38 kV fuse links cannot be used with an isolation link. DF NH Fuse Links and Bases. • The fuse monitor requires that the supply side of the XLP Fuse link size Operating class Rated voltage (V d. 47 Safety comes first! FN SDFs come with the following safety features as a standard offering: Terminal Shrouds on both line and load side; Phase barriers View datasheets for Medium Voltage Fuse Catalog by Eaton Download PDF Datasheet Disconnect † 2CLE-PDM-C 2CLE-GDM-C CLE-DL-C CLE-DF-C. — Reliable in extreme conditions ABB fuse links guarantee maximum protection against all faults. 5KV, 8. Check out our wide range of products. Keywords: 240-48; dual element fuse link; fuse; fuse link; bay-o-net; bon Created Date transient, 80 percent of its fuses are blown unnecessarily. 3x38mm; 32A; 690VAC; Poles: 1 - This product is available in Transfer Multisort Elektronik. Bussmann series 2020 Retail (Automotive and hardware) product catalog Low-Peak Upgrade brochure Advance your knowledge of electrical safety, circuit protection technology, code compliance and more with Bussmann University . DF Cylindrical Fuses. The entire fuse Product Selection Guide - Circuit Protection, Fuses, Power DFJ Class J high speed fuses Catalog symbol: • DFJ-_ Description: The Bussmann™ series DFJ drive fuse is a high speed, current-limiting fuse that provides maximum protection for AC and DC drives and controllers and meet NEC® branch circuit protection requirements. Compact versions in low rated currents of every size. 46 • UL Listed, Guide JEEG, File E240398. Ground connection 7. As new products were developed throughout the years, fuse sizes evolved to fill the various electrical circuit protection needs. Search in DF ELECTRIC catalogs and technical brochures on DirectIndustry and find the information you need in 1 click. R-Rated fuses will melt in a range of 15 to 35 seconds at a FuSe-LinKS. ampere catalog ampere catalog ampere catalog ampere catalog. 020"W×. OR LESS 250 VOLTS D. A hotstick is used to remove the Bay-O-Net fuse cartridge holder from non-pressurized apparatus. Blown Fuse refer to Catalog 9080CT0801. Fuse holders & bases for miniature fuses. TXID 07945802565 • • 1. Dimensions (see catalog number tables for values) 3. 8KV AND 38KV FERRULE MOUNTED FUSES Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection . High voltage fuses, british standard (HHB): Download. Available with or without fusing indicator. eaton. PDF) [ZH] Fusegear. Specifically designed, this fuse protects against overloads and short circuits, intended as protection of cables, power lines and overall equipment. The BS fuse holders are designed for safety & easy operation. High voltage fuses, french standard (HHF): Download. DOMESTIC FUSE HOLDERS PMD SINGLE-PHASE DOMESTIC FUSE HOLDERS (FRENCH STANDARD) Modular fuse holders for domestic cylindrical fuse links. 10 Pages UL4248-1 Fuse holders UL486E Wiring terminals CSA C22. Related products. Antenna for long-range communications R Recloser CB Circuit breaker FS Fusesaver™ SS Substation 25 Fuse holder and partner fuse DONGFENG Tractor Operator Manuals & Parts Manuals PDF - zb25, zb35, zb45, zb65, zb75, zb85, DF504G3, zb25 Engine Parts Catalog etc. All industrial fuse-links have the option of a Description Catalog section Selecting fused circuit protection Introduction Low voltage branch circuit fuses 1 Low voltage supplemental fuses and limiters 2 Electronic, PCB and small dimension fuses 3 High speed fuses 4 IEC and British Standard fuses 5 Photovoltaic fuses, holders and blocks 6 Medium voltage fuses 7 Fuse blocks and holders 8 FUSE Circuit Protection Products and Mounting Accessories Fuse Characteristics, Terms and Consideration Factors The purpose of this introductory section is to promote a better understanding of both fuses and common application details within circuit design. The higher the voltage, the better the protection that can be achieved with the Carling Technologies PDF. 800ID JTD 8⁄ 10 ID 10 0JTD. Most ratings are available with an optional indicator. This catalog contains a full range of accurate, rugged and reliable calibration solutions for field and bench applications. 1. The range comprises fuse-links from size NH000 up to NH4, with rated currents from 2A up to 1250A. es PMX industrial modular fuse holders for cylindrical fuse links CYLINDRICAL Certifications 10x3 se holder 2023. Product Ranges: This new fuse incorporates over 20 years of field-tested Hi-Tech full-range fuse technology combined with a new visual indicating mechanism. Electrical and Industrial | Power management solutions | Eaton * See catalog number tables for voltages, ampacities and interrupting ratings by catalog number. Special Fuses catalogue. Copyright 2024 Standard Motor Products, Inc. D fuse links gG class for use as general protection against overloads and short circuits, intended as domestic protection or in some industrial equipment. Date: FuPact-GSB-TC-Catalogue_SEHK_FUG_CA_2303. Modular Fuse Holders, TeSys DF . 31 (84. Whenever the temperature rises abnormally in a fuse-link Mersen patented thermal striker trips and triggers either a mechanical or an electronic system that will open the circuit (sketch). Fluke Calibration. 125 (4. The fuse monitor provides status indications and control impulses in case of operated fuse link. High voltage fuses, DIN standard (HHD): Download. 25 JTD1. 7 Expulsion Fuses RBA/RDB Type Fuses (Including Superseded BA Fuses) RBA and RDB Details 125NHG00B - Eaton Bussmann series low voltage NH Fuse, Live gripping lug, 500V, 125A, 120 kAIC, Combination fuse status indicator,Blade end connection, Class C gL/gG, Square-body with knife blade contact, Metal plated copper contact plate al dric lins cy fuse e pag lders fuse ho ks s dular holder cc class fuse-lin t fuse mx mo or lf drica fuses cylinindrical | gg l 02 | am cy 04 ac sf | p 06 pmc comp use holder olders | 09 pmx-cc f lar fuse h e holders 09| pmf modu fixing fus 10| sc screw fuse bases use holders 11| bac open l mounting f fuse holders 11| pmp pane connection use-links 12| pmb plug ct for φ10 f 12| lip conta c 12| Consult DF ELECTRIC's entire Special Fuses catalogue catalogue on DirectIndustry. , Designed & Developed by Multimedia Solutions V14-T2-54 Volume 14—Fuses CA08100016E—August 2011 www. 106. Medium voltage fuses Contents Fuse range selection 2 Fusarc CF, Soléfuse, Tépéfuse, MGK MV limiting fuses with thermal striker Fuse and limitation curves 10 Fuse and limitation curves 12 Metering transformer protection 13 References, characteristics and curves 14 Selection and usage guide General - Transformer protection 15 Transformer Fuse is a protective device and it breaks current when the wire inside melts and protects its circuit against over current risks. Auxiliary power connection 8. The range comprises the following fuse links: Size 10x38 1000V DC 1A to 20A Specifications Voltage Range AC: 550 V - 1300 V DC: 500 V - 1000 V Amperage Range 40 A - 2000 A Interrupting Range AC: 100 kA - 200 kA DC: 150 kA Time Constant 10ms Microswitch Yes The fuse monitor is a fuse blown monitoring and indication device. DF Electric 420002 cylindrical fuse links gG class that indicates fuse-links with a full-range breaking capacity for general application. They have been developed to offer a DC compact, safety and economic protection solution in photovoltaic installations where due to the increase of the power and technologic evolution, no-load voltages above 800V DC can be FUSE LINKS FUSE LINKS aM NH type (NH) fuse-links aM class for motor protection, with top indicator. The fuse monitor is connected to the gripping lugs of the fuses. The drive fuse has the lowest I2t of any branch circuit fuse to protect Electrical and Industrial | Power management solutions | Eaton USESI Careers L&T hrc fuse catalogue. Email: quote@powerfuse. IP20 protection index (finger safe). 00 In – 20ms Clip-in BS88 Fuse Links 6 Safeclip Fuse Holders 7 British type Bolt-in Fuse Links 8 - 11 Redspot Fuse Holders & Accessories 12 - 13 DIN Blade Fuse Links & Accessories 14 - 17 DIN Blade Fuse Bases & Disconnects 18 - 19 Modular Fuse Holders 20 Ferrule Fuse Links - Industrial 21 - 22 Bottle Fuses 23 Service Fuse Fittings 24 - 25 Ferrule Fuse Links Download the latest commercial vehicle catalog from Littelfuse, the leading supplier of fuses, semiconductors, switches and sensors for automotive applications. all fuse ratings, are in accordance with CEF, CEF-S, CEF-VT and CMF type fuses manufactured to date and with IEC standards. Fuseholders1 Conventional Thermal Current (lth) Size of Cartridge Fuse or Link Composition P=Poles 15- 5 A c c e s s o r i e s Fuse kits and accessories 15 Clip clamps and rail adapters (DIN and American) BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton. Page: 1/10. Models with fuse clip contacts, for mounting panel or in-line. They are used for blade & offset tag of fuses upto 100A. Screw cap gauge pieces Fuse rating rejection insert to prevent incorrect fuse rating from being installed. 1 In – 30 min 100mA 2. Get up-to-date and detailed information about our EFEN products in our pdf cataloges. COM-UL-certificate-E113357v1s5-SP43-fuse-holders Title. 041"L×. 26) 2 P 6 DFCC2V 0. High breaking capacity: 80kA for Cylindrical & BS Type & 100kA for DIN Type. • Current-limiting fuses provide positive interruption even on low fault currents. Agency information: • E-Rated fuses meet the performance characteristics of ANSI C37. Check out our interactive digital publication, powered by Dirxion, the ultimate flip book platform. High voltage fuses, General Information: Download. Digital Update: 2022/23 Cataloguee. Single-phase models or single-phase+neutral in only one module. supplier catalogues. Fuses may be operated up to the maximum voltage stated in the rating. All fuse-links include an indicator or striker and can accept a microswitch for remote D and D0 fuse links and bases EATON www. The user interface makes reading and searching easy. number 4 aR 850/1250 1400 800,000 5,000,000 195 170M7217 Data Sheets: 170K6640, 170K6642 Dimensions - mm 8 EATON Bussmann series traction fuse links catalogue . HRC Fuse Link range covers ratings from 2A to 800A. Communications module 4. Markings on the striker label and rating plate of fuse with TCU: Catalog Symbol: NH_G-690 Approvals: IEC269,VDE 0636 Description:A square bodied range of industrial fuse links for wide variety of applications where 690V is needed. Federal NH fuse and fuse base are manufactured in accordance with CE. HCR FORM II Page 1 of 3 BIF Doc #4131 Bussmann ® Dimensional Data CATALOG SYMBOL: H07CB, K07CB, KO7CRB, L14CB, M14CB, L09CB, M09CB, P09CB, P11CB AND R11CB CERAMIC BODYFUSE 600 VOLTS A. These current-limiting fuses will melt at current that can be as low as 1 . Industrial modular fuse holders for cylindrical fuse links · Available in a extended range of different versions with fuse indicator, with microswitch, 690V, 24 V DC, Microswitch FUSING + PRE-BREAKING + FUSE LINK DETECTION. Legal | Privacy. Screw cap fuse links carriers Screws into fuse base. The fuses in this catalog range in size from the approximately 0402 chip size (. R-Rated fuses also have defined current response times specified by ANSI C37. ) Rated current (Amps) I²t (A²s) Watts loss (W) Catalogue Pre-arcing Total at 1250 V a. Server IP Address: 198. PDF Download: English Surge Protection Devices Catalog 63NHG000B - Eaton Bussmann series low voltage NH Fuse, Live gripping lug, 500V, 63A, 120 kAIC, Combination fuse status indicator, Blade end connection, Class C gL/gG, Square-body with knife blade contact, Metal plated copper contact plate, Ceramic body E066 Hig Voltage pparatus High Voltage Apparatus Stock Code 605066 6. If you need to find a replacement to another manufacturer’s glass tube, low voltage branch or supplementary or high speed fuse, or fuse block or holder, use this quick cross reference FuseFinder to identify the Bussmann series replacement. 8×32 PMC Compact fuse holders; 10×38 PMC Compact fuse holders; PMX CC fuse holders; BAC Open fuse bases. The Mersen fuse-link with thermal striker is designed for switch-fuse combinations and opens the circuit when an extended over current causes temperature rise. 56) Accessories Auxiliary early break and “blown fuse” signalling contacts (2) Size of cartridge fuse or link mm (inch) Number of contacts Sold in lots of Catalog numbers Weight kg Lawson Fuses Dummy fuse “neutrals” Fuse pullers Fuse pullers are available in various sizes to help safely and easily extract fuses from blocks and holders. Rated voltages: 3 kV – 40. Made of ceramic tube with high withstand to internal pressure and thermal shock, that allow a high breaking capacity in a reduced physical space. 8 JTD. small variations from the controlled test conditions can greatly affect the predicted life of a fuse when it is loaded to its nominal A letter “C” in the catalog number indicates that the fuseholder can be fitted with auxiliary early break, “blown fuse” signaling and “fuse present” signaling contacts. es Knife type NH gG 500V fuse links with top indicator These high breaking capacity fuse-links are intended for protection of power lines and equipment, against overloads and short-circuits with rated voltages up to 500V AC (+10%). The complete range conforms to IS 13703 (Part 2) / IEC 60269-2 standards For additional information view the HPBB open style fuse block data sheet Catalog Numbers (amps) HP10NH1 1000V DC Size NH1 Photovoltaic Fuses About the HP10NH1 Fuse Mersen’s HP10NH1 photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Packaging:All fuse links are packed in 3’s. From chip fuses to bolted fuses for large currents, we have a repertoire of every kind of product. Fuse or isolating link 5. gF fuse-links are for domestic use. Tightening screws loosely may cause malfunction or the body to catch on fire. CYLINDRICAL FUSES FUSES gG CYLINDRICAL class for use as general protection against overloads and short circuits, intended as protection of Cylindrical fuse links gG cables, power lines and equipment. ID: 1SXF300002C2001, All variants of poles are available in different fuse sizes/rated operational currents from 100A up to 630A TeSyS fuse-disconnector - 1P - 25A - fuse size 10 x 38 mm Main Range of product TeSys fuse-disconnector Product or component type Fuse-disconnector Device short name DF10 Poles description 1P Complementary Mounting support Rail Mounting position Vertical +/- 23° Control type Toggle [Ie] rated operational current 32 A for power circuit Class gL-gG Industrial Cylindrical Fuses Breaking Capacity: 20 kA Confirming to IEC60269-1-2, EN60269-1-2, CE RoHS Approval MEDIUM VOLTAGE FUSES 2. HRC Fuse Link Range. Installation No special tools are required. See catalog numbers. We may also collect personal data such as your name, job title, company name, address, email address and telephone number either directly from you or by combining information we collect through other sources. I'd like to receive news and commercial info from Schneider Electric and its affiliates via electronic communication means such as email, and I agree to the collection of information on the opening and clicks on these emails (using invisible pixels in the images), to measure performance of our communications and improve them. txt) or read book online for free. High voltage fuses, special designs (HHx): Download When you use our website, we collect personal data about you and your use of the Website, through cookies and analytics tools. 0_EFEN_Main_Catalog. Acrobat Reader lets you read, sign, comment, and interact with any type of PDF file. Đi đến nội dung chính. A Bussmann ® Form No. HRC FORM II Current Limiting Fuses HRC FORM II Ceramic Body Form No. Catalog no. They meet the BS88 part 1 and 2 and IEC 60269-1 and -2 standards. To differentiate fuses with a TCU from standard fuses, additional catalogue numbers have been generated and special markings on the fuse body are provided. e . Product Catalog symbol/type Fuses 5x15 mm fuses C515, C519 time-delay 2 C518, C520 fast-acting C517 fast acting 3 IEC 5x20 mm fuses GDB, S500, S500-V fast-acting * See catalog number tables for voltages, ampacities and interrupting ratings by catalog number. Composition. Sections include a wide range of multifunction, mA loop, pressure calibrators, temperature calibrators and data acquisition products. 41) 3 P 4 DFCC3V 0. fuses FP-4 1-3/4" to 2-1/2 UltraSafeTM Fuse Holders FUSE BLOCKS & HOLDERS ULTRASAFE MODULAR FUSE HOLDERS FOR MIDGET AND CLASS CC FUSES Mersen UltraSafe Modular Fuse holders introduce a new level of safety for Class CC (USCC) and Midget 1-1/2" x 13/32" (USM) AC and DC-rated fuses up to 30 amperes. 2 Nº 4248-1 Fuse holder assemblies CSA 22. 75KV, 5. g. Knife type NH gG 500V fuse links with top indicator. I n 170M7350 NH1 32 80 2000 8 170M7351 NH1 40 185 3000 9 170M7352 PSF 5 x 20mm Miniature Glass Fuse Links – Fast Acting Applicable Standards IEC 60127-2 Std. C. pdf: 2016-09-19: 50. • E-Rated fuses are physically dimensioned for easy installation in existing hardware. In addition to carrying standard and specialty products from Mersen, Norberg~IES specializes in explosion proof hazardous location enclosures in our 30,000 square foot facility located in the heartland of America. The Hi-Tech Valiant current-limiting fuse's special construction contains the expulsive fragments that could otherwise be emitted during fuse operation - fragments that could fall on dry vegetation and ignite a wildfire. 800TXID 07945802564 • • 1 JTD001ID JTD 1ID 10 0JTD001. NH More than a safeguard for your power supply, it's how you protect your two most valuable assets: your people and your equipment. Fuse Catalog symbol Blocks DIN-Rail holders Panel mount holders In-line holders PCB fuseclips Cable limiters K_ — — — — — UH_ — — — — — Welder limiters Chordn NH Fuse-links, sizes 00C, 00, 0, 01, 02 and 03 are rated 690 Volts AC with breaking capacities of 120kA. Product Ranges: Available in sizes 5x20 and 6x32 with quick acting (F) or Time lag (T) characteristics. India Our Brands Professionals; Access Our Online Store; AC0479EN_052020-OK. Only fusion Both versions delivered with 3 pre-insulated terminals (fast-on 2,8 x 0,5) NC (Normally closed) NO(Normally Open) contacts 1. gt lz xv db il xi px mi ys ye